Disassembly Procedures
!
4. Release locking tab and slide sensor to release.
42
WARNING
S t r a i n
Relief's
16022808 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
NOTE: When installing a new Tub DisplacementSensor,
apply a small amount of grease provided with the
new Tub Displacement Sensor to the terminal
area. Slide the wire harness connector onto the
sensor. Reroute wires through wire clips and
strain relief's.