Interfacing to the External I/O
An external sensor that senses physical changes in the area Video Server is monitoring
can activate some features of IVS-100. These changes can include intrusion detection or
certain physical change in the monitored area. For examples, the external sensor can be
a door switch or an infrared motion detector. These devices are customer provided, and
are available from dealers who carry surveillance and security products. Electrically, they
must be able to provide a momentary contact closure.
This Video Server provides a general I/O terminal block with two digital inputs and two
outputs for device control. Pin 1 and 2 can be connected to an external sensor 1. Pin 2
and 3 can be connected to an external sensor 2. Both of the inputs, the voltage will be
monitored from the initial state 'LOW'. The relay switch of pin 4, 5 and 6 can be used to
turn on or off the external device. The relay switch of pin 7 and pin 8 can be used to turn
on or off the external device. External Inputs/Outputs are working independently.
Pin
1
2
3
4
5
6
7
Function
Alarm Input #1 (A). Max 24VDC, 12mA.
Alarm Input #1/2 (K).
Alarm Input #2 (A). Max 24VDC, 12mA
Alarm Output #1 (NC). Max 24VDC, 1A
Alarm Output #1 (COM)
Alarm Output #1 (NO)
Alarm Output #2 (COM). Max 24VDC, 1A
63/79