Wiring The Fault Alarm Contact - Planet IPOE-171-60W User Manual

Industrial 802.3bt multi-gigabit poe++ injector
Hide thumbs Also See for IPOE-171-60W:
Table of Contents

Advertisement

3.4 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. After inserting the wires,
the IPOE-171 series will detect the fault status of the power failure
and then form an open circuit. The following illustration shows an
application example for wiring the fault alarm contacts.
1. The wire gauge for the terminal block should be in the
range between 12 ~ 24 AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A currents.
Note
Fault Alarm Contacts
12
Figure 7: Fault Pin of Terminal Block.
Fault
Figure 8: Fault Alarm Contact
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipoe-171-95w

Table of Contents