Section 6 Troubleshooting - Pentair sta-rite 5PXF Installation And User Manual

High performance pump
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
7
Priming the Pump
1. The pump strainer pot must be filled with water before the pump is initially started. Follow these steps to prime the pump.
a. Remove the pump lid and locking ring.
b. Fill the pump strainer pot with water.
c. Reassemble the pump lid and locking ring onto the strainer pot. The pump is now ready to prime.
d. Open the air release valve on the filter, and stand clear of the filter.
e. Turn on the switch or time clock.
f. When water comes out of the air release valve, close the valve. The system should now be free of air and
recirculating water to and from the pool.
g. This pump will prime within 13 minutes. Do not allow your pump to run longer than this time without
developing full flow. If the pump does not prime, see the "Troubleshooting" section below.
Section 6
Troubleshooting
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.
Improperly installation will create an electrical hazard which could result in death or serious injury to pool users, installers,
or others due to electrical shock, and may also cause damage to property.
1. If you are not familiar with your pool filtering system and/or heater:
a. DO NOT attempt to adjust or service without consulting your dealer, or a qualified pool professional.
b. Read the entire Installation & User's Guide before attempting to use, service or adjust the pool filtering
system or heater.
2. SWITCH OFF power to the pump before attempting service or repair.
Problems and Corrective Actions
Problem
Pump Will Not Prime — too much air
Pump Will Not Prime — not enough
water
Pump strainer clogged
Pump strainer gasket defective
REDUCED CAPACITY and/or HEAD
Air pockets or leaks in suction line
Pump Will Not Prime — too much air
Clogged impeller
Section 7
Technical data
Technical data at the end of this manual on page 38-39.
Section 8
Spare parts
An illustrated spare parts list can be found at:
Corrective Action
Check suction piping and valve on any suction gate valves.
Secure lid on pump strainer pot and make sure lid gasket is in place.
Check water level to make sure skimmer is not drawing air.
Make sure suction lines, pump strainer, and pump volute are full of water.
Make sure valve on suction line is working and open
Check water level to make sure water is available through skimmer.
Clean pump strainer pot.
Replace gasket.
Check suction piping and valve on any suction gate valves.
Secure lid on pump strainer pot and make sure lid gasket is in place.
Check water level to make sure skimmer is not drawing air.
Switch OFF electrical power at the house circuit breakers to the pump.
Remove the nuts that secure the volute to the seal plate.
Slide the motor and seal plate away from the volute.
Clean debris from impeller.
If debris cannot be removed, complete the following steps.
(1) Remove impeller reverse screw and O-ring.
(2) Remove, clean and reinstall impeller.
(3) Reinstall anti-spin bolt.
Reinstall diffuser and O-Ring.
Reinstall motor and seal plate into volute.
Reinstall hardware around seal plate and volute and tighten securely.
Clean suction trap.
www.pentairpooleurope.com

Advertisement

Table of Contents
loading

Table of Contents