3
3.2
Separation roller unit
Purpose
To return to the normal operation as soon as possible when a decrease in the
paper feedability is found due to the deterioration of the separation roller.
Procedure for the removal
1
Remove the pick-up roller unit. For details, refer to "Procedure for the
removal" on page 3-1.
2
Remove the 2 screws and then remove the auxiliary roller assembly.
3
Remove the C-ring and then remove the gear.
3-8
Screw
C-ring
Bearing
Auxiliary roller
assembly
Gear
Separation
roller unit
CMS Replacement instructions
DF-603