Wiring
continued
Model D or DT sensor (except D600) wiring to Model 3500 with I/O cable
Model D or DT
sensor terminals
Brown
Red
Orange
Yellow
Green
Blue
Violet
Gray
White
For DT sensor junction box
information, see page 20.
Model D or DT sensor (except D600) wiring to Model 3500 with screw or solder terminals
Model D or DT
sensor terminals
Brown
Red
Orange
Yellow
Green
Blue
Violet
Gray
White
For DT sensor junction box
information, see page 20.
22
1. Locate the wires by color and terminal number.
2. Insert the stripped ends of the individual wires into the terminal
blocks. No bare wires should remain exposed.
• At the sensor, connect wiring inside the junction box.
• At the transmitter, connect wiring to the transmitter's intrinsically
safe terminals for sensor wiring.
3. Tighten the screws to hold the wires in place.
4. Ensure integrity of gaskets, then tightly close and seal the
junction-box cover and all housing covers on the transmitter.
Drain wires from a 9-wire cable must be clipped at the
sensor end and insulated with heat-shrink wrapping.
Failure to properly terminate drain wires will cause
sensor error.
Flowmeter
Maximum cable length 1000 ft. (300 m)
Brown
Red
Clip drain wire back
Green
White
Clip drain wire back
Blue
Gray
Clip drain wire back
Orange
Violet
Yellow
Clip drain wire back
Prepare cable in accordance with the instructions
that are shipped with the cable
Flowmeter
Maximum cable length 1000 ft. (300 m)
Brown
Red
Clip drain wire back
Green
White
Clip drain wire back
Blue
Gray
Clip drain wire back
Orange
Violet
Yellow
Clip drain wire back
Prepare cable in accordance with the instructions
that are shipped with the cable
CAUTION
cable
Black
(Drains from all
wire sets)
Brown
Red
Green
White
Blue
Gray
Orange
Violet
Yellow
cable
Black
(Drains from all
wire sets)
Brown
Red
Green
White
Blue
Gray
Orange
Violet
Yellow
Micro Motion
Model 3500
with I/O cable
Not approved for intrinsic safety
in Europe
Model 3500
with screw-type or
solder-tail terminals
Yellow
c4
Violet
c6
Green
c8
Blue
c10
Brown
c12
®
Model D and DT Sensors Instruction Manual
Connect outer
braid of shielded or
armored cable
a4
Black (Drains)
a6
Orange
a8
White
a10
Gray
a12
Red