16

Data protocol

DTR mode
This mode is accessed when the DIP switch 1-6 is set to ON.
Signals are controlled using the DTR line as a BUSY flag.
RXD
DTR
Printing
Power ON
Immediately after power on (provided that no error occurs), the printer sets DTR
to "SPACE" to indicate that it is ready to receive data. When the host detects
that DTR is in "SPACE" condition, it begins sending text data over the RXD
line.
When the printer's remaining buffer space falls to *256 bytes or less, the printer
sets DTR to "MARK." The host responds by halting the data transfer. However,
note that the printer remains capable of receiving data until the buffer becomes
full.
Available buffer space increases as the printer prints the buffered data. When
the printer has cleared all but the last *256 bytes of data, it sets DTR back to
"SPACE" to indicate that it is ready to receive more data.
Data buffer full Nearly full
*256 bytes
remaining
DTR
"MARK"
* 16 bytes when the buffer size is set to 45 bytes
Data
Buffer full
Data
Buffer empty
Nearly empty
Data
Empty
*256 bytes
DTR
"SPACE"