Electrical Requirements - Fisher & Paykel DE60FA2 Installation Instructions And User Manual

Dryers de70fa* & dg70fa* user guide (english, spanish)
Table of Contents

Advertisement

Available languages

Available languages

Electrical Requirements for Electric Models Only
Note:
The wiring diagram is inside the control console.
The dryer must be plugged into or
connected to an individual branch circuit,
do not use an extension cord.
Ensure proper ground exists before use.
The power supply must be 220/240V or
208V, 60 Hz approved alternating current
electrical service. The electrical service
requirements can be found on the data
label that is located on the console back.
A 30-ampere fuse or circuit breaker is
required on each of the lines.
If a power cord is used, the cord must be plugged into a 30-ampere receptacle.
The power cord is NOT provided with U.S. electric model dryers.
This dryer is supplied with the cabinet grounded through the neutral on the terminal block. If
the dryer is to be installed in (1) a new branch installation, (2) a mobile home, (3) a recreational
vehicle, (4) an area where local codes do not permit grounding through the neutral conductor,
the appliance grounding link must be removed and a 4-wire power cord/cable or a separate
grounding wire must be used.
Do not reuse a power supply cord/cable from an old dryer. The power cord/cable electric supply
wiring must be retained at the dryer cabinet with a suitable UL listed strain relief.
22
WARNING
Electric Shock Hazard
Use a new UL/CSA approved 30-ampere power cord or direct wire
cable.
Use a UL approved strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal.
On all four wire installations remove the grounding link and
connect the ground wire to the green ground connecting screw.
Connect remaining 2 supply wires to remaining 2 terminals.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
If local codes permit, an external
ground wire (not provided),
which meets local codes, may
be added by attaching to the
green ground screw on the rear
of the dryer, and to a grounded
metal cold water pipe or other
established ground.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Dg60fa2De70fa1Dg70fa1

Table of Contents