External Venting Options

• Kits are available that allow the dryer to be vented upwards or to the
side.
• The dryer can be vented directly through the wall with a kit, in
combination with the duct adaptor supplied with the dryer.
The vent system should be less than two metres long
with no more than three 90⁰ bends.
Internal Venting
Front venting is the only option for internal venting. The dryer is set up for
front venting when it leaves the factory.
Where possible all efforts should be made to vent the
dryer externally to avoid moisture build up around the
dryer

Electrical Connection

1. This appliance must be connected to a 220V – 240V, 50Hz,
sinusoidal, 10A electrical supply.
2. Uncoil the power cord, remove and discard the plastic pin cover and
plug into a power socket.
3. Connect the appliance to an earthed outlet protected by a fuse of
suitable capacity.
◦ Check the power cord for damage and make sure it is not
squashed or twisted when installing the dryer.
◦ Always remove the power cord from the power socket by the
plug, not by the cord.
https://producthelp.fisherpaykel.com/au/Dry/Dryers/Vented/DE4060M1/User_Guide_DE4060M1/03_Installation_Instructions
External venting with kit part
number PD-DK4W
External venting with kit part
number PD-SVHCW4
Updated: Sun, 27 Aug 2023 10:37:02 GMT