Fast Test Cycle

4.3
Press and hold KEYLOCK, then START/PAUSE for 5 seconds.
All LEDs & LCD segments except Keylock are illuminated.
Press POWER twice.
"FC" will show in the display (integrated and flat door models: Heavy,
Normal, Delicate, Rinse LEDs showing).
Press START/PAUSE twice.
The 8 minute fast test cycle will start.
Press POWER to exit.

Continuous Cycle

4.4
Press and hold KEYLOCK, then START/PAUSE for 5 seconds.
All LEDs & LCD segments except Keylock are illuminated.
Press POWER three times.
"CC" will show in the display (integrated and flat door models: Heavy,
Normal, Rinse LEDs showing).
Press START/PAUSE.
The last cycle that had been selected prior to going into diagnostics mode
will be run continuously.
Press POWER to exit.
Temperature & Voltage Display Mode
4.5
(Not available on integrated or flat door models.)
Start a wash cycle running.
Press & hold KEYLOCK for 4 seconds.
Keylock will be activated.
Press & hold START/PAUSE for 8 seconds.
LCD will now alternate between °C symbol and the water temperature.
Press START/PAUSE.
LCD will now alternate between °E symbol and the controller's rail voltage.
Press & hold KEYLOCK for 4 seconds.
Keylock is deactivated.
Press POWER to exit.