Fast Test Cycle; Continuous Cycle Test Mode - Fisher & Paykel DishDrawer DS605 Diagnostic Service Manual

Dishdrawer
Hide thumbs Also See for DishDrawer DS605:
Table of Contents

Advertisement

Fast Test Cycle

3.6
WARNING: Only run this cycle if the DishDrawer™ is connected to the water
supply.
This level runs an 8 minute fast test cycle.
Press POWER to skip Fast Test Cycle and advance to the next level.
Press START/PAUSE to enter Fast Test cycle.
Once Fast Test Cycle is selected the DishDrawer™ goes into standby mode
and 8 minutes will be showing on the display. The test cycle is started by
pressing START/PAUSE, and the following components are run during the 8
minute cycle that follows:- Lid motors, fill valve, wash motor, element, drain
motor, drying fan.
Press POWER to exit at any time.

Continuous Cycle Test Mode

3.7
In this level the DishDrawer™ can be run continuously in any wash cycle.
Once the cycle has finished, the DishDrawer™ automatically restarts the
same wash cycle.
Press POWER to skip Continuous Cycle. As this is the last level, doing this
will exit diagnostics.
Press START/PAUSE to enter Continuous Cycle.
Once selected, the LCD backlight flashes on and off to indicate the
DishDrawer™ is in continuous cycle and the cycle starts straight away (for
integrated and flat door models the LED above the start/pause button will be
orange instead of green to indicate the DishDrawer™ is running in continuous
cycle). It will run the last cycle that had been selected prior to going into
diagnostics mode.
If it is desired to run a different cycle, exit diagnostics, turn the DishDrawer™
on as normal and select the cycle required. Then turn the DishDrawer™ off
again, re-enter diagnostics and restart the Continuous Cycle as above.
Press POWER to Exit at any time.
11
599464

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dishdrawer dd605

Table of Contents