Fisher & Paykel DishDrawer DS605 Diagnostic Service Manual page 23

Dishdrawer
Hide thumbs Also See for DishDrawer DS605:
Table of Contents

Advertisement

F2 Motor Not Rotating
The controller has not sensed the motor rotating.
The product will pause the wash program, log the fault, and report to the
user.
PRIMARY ACTION
- Check the rotor is free to turn.
- Check that power is available at controller (e.g. do the lid actuators run in
diagnostics).
SECONDARY ACTION
- Check whether the rotor is not moving or is vibrating in diagnostics.
- If vibrating, check the hall sensor is properly fitted, check that the motor
stator connections are OK.
- If not moving, check the connections at the controller and the motor.
- Check the resistance of the motor windings.
TERTIARY ACTION
- Check if a replacement hall sensor solves problem.
- Check if a replacement controller solves problem.
- Check if a replacement PCB mains filter solves problem.