7.REMOVING JAMMED STAPLES (OPTIONAL) (Cont.)
8
Return the saddle staple to its original
position.
- Pull the handle of the saddle stitch holder (1) toward you and turn
it (2) 90º in the direction of the arrow.
9
Return the saddle stitch unit to its original
position.
Make sure that A3, A4-R or B4 paper is
10
set.
- If any of the above paper sizes is not set, test stapling cannot be
performed.
Close the front cover of the finisher. Then
11
test stapling is automatically performed
on a blank sheet.
- This is performed to avoid empty stitching.
If there is a test stapling failure and "Check staple cartridge"
remains, repeat the above procedure from step 1 to 11.
12
278
12.WHEN THE GRAPHIC SYMBOLS BLINK ON THE TOUCH PANEL