Redundant Power Cord Connection - HP Cluster Platform Interconnects v2010 Manual

Gigabit ethernet interconnect guide
Hide thumbs Also See for Cluster Platform Interconnects v2010:
Table of Contents

Advertisement

3.
Insert the power supply into the opening making sure it is centered in the opening. This
will assure that the guide rails on the bottom of the power supply engage the rails on the
bottom of the switch. Then, slide the power supply all the way in until its bulkhead contacts
the back face of the switch.
4.
Tighten the four retaining screws that hold the power supply in place until the screws are
secure. The screws can be tightened with either a flat-bladed or Torx T-10 screwdriver. Be
careful not to overtighten the screws
5.
Connect the power cord supplied with the power supply to the power connector, as shown
in
Figure
the second power supply should be connected to a different AC power source from the other
supply. Then, if one AC power source fails, the switch will continue to run.
Figure 5-5 Redundant Power Cord Connection
Item
1
6.
Verify that the power supply is installed correctly by checking the LEDs on the front of the
switch
(Figure
be blinking simultaneously with the Fault LED until that new power supply is connected
to an AC power source. Once it is connected to AC power, the Power Status LED will be on
continuously and not blinking, and the Fault LED will stop blinking.
42
HP ProCurve 5308xl
5-5, and then into a properly grounded electrical outlet. To provide true redundancy,
Description
Redundant power supply cord connection
5-6). The Power Status LED for the power supply you have just installed will
1