Power Cycling After Using JET

After using JET, you must recycle the system power because the offline diagnostic can deallocate
the CPUs.
To remove the 48 V power, run the MP pe command. Then cycle the ac breakers on the rear of
the cabinets. Leave power off for about 30 seconds to allow the backplane CSRs to reset.
IMPORTANT:
cabinets in the proper sequence.

Offline Diagnostic Environment

Now that scan has been run, you can run all the appropriate diagnostics for this system. See the
offline diagnostic environment (ODE) documentation for instructions.

Attaching the Rear Kick Plates

Kick plates protect cables from accidentally being disconnected or damaged and add an attractive
cosmetic touch to the cabinet. You must attach three metal kick plates to the bottom rear of the
cabinet.
To install the kick plates, follow these steps:
1.
Hold the left kick plate in position and attach a clip nut (0590-2318) on the cabinet column
next to the hole in the flange at the top of the kick plate
2.
Using a screw (0515-0671) and a T-25 driver, attach the flange on the kick plate to the nut
clip.
3.
Using a T- 1 0 driver and a screw, attach the bottom of the kick plate to the center hole in the
leveling foot.
After scan testing successfully completes, reset the complex by cycling the AC
If the complex has any IOX cabinets with IDs 8 or 9, you must power cycle these
(Figure
54).