HP 6125G Configuration Manual page 21

High availability configuration guide
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Use the display oam configuration command to display the Ethernet OAM configuration. For
example:
# Display the Ethernet OAM configuration on Device A.
[DeviceA] display oam configuration
Configuration of the link event window/threshold :
--------------------------------------------------------------------------
Errored-symbol Event period(in seconds)
Errored-symbol Event threshold
Errored-frame Event period(in seconds)
Errored-frame Event threshold
Errored-frame-period Event period(in ms)
Errored-frame-period Event threshold
Errored-frame-seconds Event period(in seconds)
Errored-frame-seconds Event threshold
The output shows that the detection period of errored frame events is 20 seconds, the detection
threshold is 10 seconds, and all the other parameters use the default values.
You can use the display oam critical-event command to display the statistics of Ethernet OAM
critical link events. For example:
# Display the statistics of Ethernet OAM critical link events on all the ports of Device A.
[DeviceA] display oam critical-event
Port
: GigabitEthernet1/0/1
Link Status : Up
Event statistic :
-------------------------------------------------------------------------
Link Fault
:0
The output shows that no critical link event occurred on the link between Device A and Device B.
You can use the display oam link-event command to display the statistics of Ethernet OAM link
error events. For example:
# Display Ethernet OAM link event statistics of the remote end of Device B.
[DeviceB] display oam link-event remote
Port :GigabitEthernet1/0/1
Link Status :Up
OAMRemoteErrFrameEvent : (ms = milliseconds)
---------------------------------------------------------------------
Event Time Stamp
Errored Frame Threshold
Error Running Total
The output shows that 35 errors occurred since Ethernet OAM was enabled on Device A, 17 of
which are caused by error frames. The link is unstable.
Dying Gasp
: 0
: 5789
: 1
: 35
14
:
1
:
1
:
20
:
10
:
1000
:
1
:
60
:
1
Critical Event
Errored FrameWindow
Errored Frame
Event Running Total
: 0
: 10(100ms)
: 3
: 17

Advertisement