HP 6125G Configuration Manual page 187

High availability configuration guide
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Step
4.
Configure the source IP
address of echo packets.
5.
Enter interface view.
6.
Configure the minimum
interval for receiving BFD
echo packets.
7.
Configure the minimum
interval for transmitting BFD
control packets.
8.
Configure the minimum
interval for receiving BFD
control packets.
9.
Configure the detection time
multiplier.
10.
Configure the authentication
mode on the interface.
In
Figure 45
for example, if you configure the Desired Min TX Interval as 100 milliseconds, Required Min
RX Interval as 300 milliseconds, and Detect Mult as 5 on Router A, and configure the Desired Min TX
Interval as 150 milliseconds, Required Min RX Interval as 400 milliseconds, and Detect Mult as 10 on
Router B,
The actual transmitting interval on Router A is 400 milliseconds, which is the greater value between
the minimum interval for transmitting BFD control packets on Router A (100 milliseconds) and the
minimum interval for receiving BFD control packets on Router B (400 milliseconds).
Command
bfd echo-source-ip ip-address
interface interface-type
interface-number
bfd min-echo-receive-interval
value
bfd min-transmit-interval value
bfd min-receive-interval value
bfd detect-multiplier value
bfd authentication-mode { md5
key-id [ cipher ] key | sha1 key-id
[ cipher ] key | simple key-id
[ cipher ] password }
180
Remarks
Optional.
The source IP address should not
be on the same network segment
as any local interface's IP address.
Otherwise, a large number of
ICMP redirect packets may be sent
from the peer, resulting in link
congestion.
N/A
Optional.
For relevant information, see the
description of the Required Min
Echo RX Interval field in
packet
format."
400 milliseconds by default.
Optional.
For relevant information, see the
description of the Desired Min TX
Interval field in
"BFD packet
format."
400 milliseconds by default.
Optional.
For relevant information, see the
description of the Required Min RX
Interval field in
"BFD packet
format."
400 milliseconds by default.
Optional.
For relevant information, see the
description of the Detect Mult field
in
"BFD packet
format."
5 by default.
Optional.
By default, the interface operates
in the non-authentication mode.
"BFD