A : Horizontal scan inversion
Three connectors are used, one for each horizontal deflection coil. When changing
the horizontal scan, insure that all three connectors are set in the same position. See
position of the connectors for the corresponding projector configuration.
B : Vertical scan inversion
Three connectors are used, one for each vertical deflection coil. When changing the
vertical scan, insure that all three connectors are set in the same position. See
position of the connectors for the corresponding projector configuration.
Top view of the connectors; upper three connectors for horizontal scan inversion,
lower three for vertical scan inversion.
Horizont al scan
connectors
Vertical scan
connectors
C : Convergence connectors
Contact side
4-6
Front / Table
Front / Ceiling
Three connectors are used.
connectors has to be changed when switching from one
configuration to another.
With an open chassis, for a front-table or a rear ceiling
configuration, the connectors must be plugged in with the
contacts upwards (away from the tubes). For a front-
ceiling or rear-table configuration, the connectors must
be plugged in with the contacts facing the tubes
INSTALLATION SET UP
Rear / Table
The position of these
5975248 BARCOVISION 701 MULTIMEDIA 070597
Rear / Ceiling