Attaching The Camera Cable; Attaching Strain Relief Cable - GE Everest Ca-Zoom 6.2 Operating Manual

Remote visual inspection
Table of Contents

Advertisement

4
8.2
Attaching Camera Cable to Camera and CCU
Step 1.
Align the small key on the cable connector with the keyway inside the connec-
tor on the camera head. Push the cable in and turn the nut until it comes to a
hard stop (fig. 2).
Note:
If the nut does not reach a hard stop, the cable may not be aligned correctly.
Realign the cable with camera head and repeat Step 1.
.
Step 2
Align the wide key on the cable connector (fig. 3) with the wide notch at the top
of the cable connector on the camera control unit. Push the cable in and turn
the nut until it locks in place.
Note:
If the nut does not lock in place, the cable may not be aligned correctly. Realign
the cable with camera control unit and repeat Step 2.
Figure 
8.3

Attaching Strain Relief Cable

The Strain Relief Cable Prevents damage to the camera connector. It must be used
whenever the camera hangs from the cable.
Step 1. Use a hex wrench to connect the two strain relief cables to opposite ends of the
camera head base.
Step 2. Use a hex wrench to remove the four screws from the strain relief collar.
Step 3. Place strain relief collar around main cable ensuring rubber grommet remains in
collar.
Step 4. Insert the four collar screws back in collar. Screw the screws in only one to two
rotations.
Step 5. Pull main cable through collar to create a slack loop between collar and camera
head.
Step 6. Tighten collar screws.