4.5
Camera Module Replacement - PTZ40
CAUTION !
Before performing any maintenance task, be sure to de-pressurize the camera unit via the
shrader valve (see page 11).
Follow these steps to replace the camera module in the event of camera failure:
• Remove Front and Back covers from camera housing by unscrewing them counterclockwise
(fig. 37).
• Remove 2 small camera module mounting screws found on the bottom of the camera hous-
ing (fig. 38)
Figure 37
• Pull the module out through the front of the camera housing. Make sure not to smudge or
dirty the lens.
• Unplug all of the harnesses attached to the camera module. CAUTION. Pay attention to
where the connectors go. There are two 2-pin connectors to attach, one connector has
been marked for easy identification.
Figure 39
®
Everest Ca-Zoom
6.2
73
Figure 38
Figure 40