14 Maintenance
4.
Cleaning
Please clean camera head after an inspection. Use regular water to wipe down cables. Use 70%
alcohol to water solution to wipe down the camera head.
4.2
Storage and Shipments
The PTZ system should always be stored in a clean and dry condition. Storage should be in areas
protected from extreme temperature and high humidity.
Storage temperature specification: -13° to 140°F (-25° to 60°C), 95% humidity.
4.3
Lamp and Lamp Window Replacement - PTZ40
CAUTION!
Before performing any maintenance task, make sure camera system is turned off and be sure
to de-pressurize the camera unit via the Schrader valve (see page 11). Make sure unit is cooled
down completely. Lamps are extremely hot.
To replace the lamp window, follow these steps:
• Remove the lamp window-retaining ring by gently prying the end of the ring with a small
screwdriver.
• Gently pry the window out of the housing.
• Carefully remove the o-ring from the groove with the supplied o-ring pick.
• Clean o-ring groove thoroughly.
• Replace o-ring with a new, well-lubricated o-ring.
• Replace lamp window.
• Install retaining ring by starting on one end and working
around the lamp housing until the entire ring is inserted into the groove.
Lamp Housing
Figure 32
Retaining Ring
®
Everest Ca-Zoom
6.2
7
Figure 33