Lamp Window Replacement - Ptz100 - GE Everest Ca-Zoom 6.2 Operating Manual

Remote visual inspection
Table of Contents

Advertisement

4.6
Lamp Window Replacement - PTZ00
CAUTION!
Before performing any maintenance task, make sure camera system is turned off and be sure to
de-pressurize the camera unit via the Schrader valve (see page 11).
To replace the lamp window, follow these steps:
• Remove the lamp window retainer by unscrewing the five screws with a Phillips screwdriver.
• Carefully remove the o-ring and windows using the supplied o-ring pick.
• Clean o-ring groove thoroughly.
• Replace lamp window.
• Replace o-ring with a new, well lubricated o-ring by pressing into gap between the window
and housing. Use a small flat-tipped screwdriver as neccessary.
• Install the window retainer with the five screws. Tighten down evenly.
• Pressure test camera housing. See "Pressure Testing" section on page 82.
Figure 43
Figure 45
Camera window retainer
®
Everest Ca-Zoom
6.2
75
Figure 44
Figure 46

Hide quick links: