Laser Installation Ptz100 - GE Everest Ca-Zoom 6.2 Operating Manual

Remote visual inspection
Table of Contents

Advertisement

6
8.7
Laser Accessory Installation (PTZ00)
Step 1.
Locate the Schrader air valve on the pan and tilt section of the camera. Remove
the Schrader air valve cover.
Step 2.
Release the pressure from the camera head
Step 3.
Remove the screw from the laser mounting port on camera head (fig. 8)
Figure 7
Step 4.
The laser accessory has a wire and connector assembly. Place the mounting plate
over the end of the harness. Make sure the "O" ring is in place on laser mounting
plate (fig. 8).
Step 5.
Connect to mating connector from camera head (fig. 9).
Step 6.
Align the mounting holes in the laser attachment with the mounting plate and
thread holes in the camera housing. Place laser attachment flush to mounting sur-
face and tighten mounting screws (fig. 10).
Figure 9
In order to insure the integrity of the camera system with laser accessory, the camera head needs
to be pressure tested. See "Pressure Testing" section on page 82.
®
Everest Ca-Zoom
6.2
Figure 8
Figure 0