Configuration Examples

The following describes examples of configuration required to use software-link features or for
system operations.
Time and Date Settings
You can also change the time and date settings via the operating system commands.
Select [Main] - [System Time].
Select [Main] - [System Date].
Link with Management Software
To control power supply of the server with NEC ESMPRO Manager via the network
Select [Advanced] - [Advanced Chipset Control] - [Wake On LAN/PME] - [Enabled].
Select [Server] - [AC LINK] - [Stay Off].
Hard Disk Drive
To check the hard disk drive status
Select [Main] - [Primary IDE Master] and check the status indications.
To configure the RAID drive with SATA hard disk drives
Select [Advanced] - [Peripheral Configuration] - [SATA Controller Mode Option] -
[Enhanced]. Then select [Advanced] - [Peripheral Configuration] - [SATA RAID] -
[Enabled], and configure the RAID drive.
IMPORTANT:
Setup Defaults] or CMOS clear. Leaving this parameter as the factory-
set value (Disabled) may destroy the data in hard disk drive.
UPS
To link power supply with the UPS
To power on the server when power is supply from the UPS
Select [Server] - [AC LINK] - [Power On].
To keep the server off-powered even when power is supplied from the UPS
Select [Server] - [AC LINK] - [Stay Off].
To keep the server off-powered even when power is supplied from the UPS if the POWER
switch was used to power off
Select [Server] - [AC LINK] - [Last State].
Be sure to set to [Enabled] after executing [Load
Configuring Your Server 4-5