System Setup

Setting up the server

Use the instructions in the Gateway 7450R Rackmount Installation Guide that
came with the server to assemble the server.
You should prepare a safe working environment before assembling the server
by following these guidelines:
Important
Obtain an adequately rated uninterruptible power supply (UPS). A UPS
protects against AC line spikes, power interruptions, and other power
fluctuations that may damage the server.
Protect the server from extreme temperature and humidity. Do not
expose it to direct sunlight, heater ducts, or other heat-generating objects.
Route external cables carefully to make sure they do not block air vents
or impede airflow.
Make sure that the inlet air temperature within the rack cabinet remains
below the specified limit of 40
Keep the server away from equipment that generates magnetic fields,
such as unshielded stereo speakers. Even a telephone placed too close to
the server may cause interference.
Keep the boxes and packing material. If you need to send
the server to Gateway for repairs, you must use the original
packaging or your warranty may be voided.
° C (104° F).
2
11
System Setup