GarrettCom Magnum ES42 Series Installation And User Manual page 56

Edge switch
Table of Contents

Advertisement

ES42 Series Edge Switches
ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum
distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 10BASE-
FL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas
for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer
cable distance and higher bandwidths as compared to copper wiring.
Media
Twisted Pair (CAT 3 or 5)
Twisted Pair (CAT 5)
Fiber (Multi-mode)
Fiber (Single-mode)
Fiber (Multi-mode)
NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mbps
and 100Mbps) be used whenever possible in order to provide flexibility in a
mixed-speed network, since ES42-series switch ports are auto-sensing for either
10 and 100Mbps. Note that the auto-cross function does not operate, if the port
is fixed or not supporting auto-negotiation.
www GarrettCom com
.
.
Installation and User Guide (05/05)
IEEE Standard
10BASE-T
100BASE-TX
100BASE-FX
100BASE-FX
100BASE-FX
49
Connector
RJ-45
RJ-45
ST, SC
SC, LC
MTRJ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF