3.6 continued, DC Power Terminals: "+", "-", gnd
GND: Terminal for "earth" or ground wire connection to the ES42H chassis
Input Voltage: 12VDC
Alarm
Contact
Terminal
12VDC
(8-15VDC)
(12V)
(8-15VDC)
Input
Power Consumption: 7 watts typical, 9 watts max.
www GarrettCom com
.
24VDC
(10-36VDC)
(12V or 24V)
(10-30VDC)
current:
0.8 amp.(12V DC)
0.4 amp max.(24V DC)
0.2 amp max.(-48V DC)
.
Installation and User Guide (05/05)
24VDC
(30-60VDC)
(12V)
(8-15VDC)
46
-48VDC
-48VDC