Electrical Connection
1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the
brewer's serial number label. Make sure the electrical service includes neutral.
2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters
during the installation process. The heaters are disabled by the control board until the tank is full of water.
The heating process will start automatically when the tank has filled.
3. A terminal block is provided for connecting the incoming power wires. Consult local codes to determine if a
cord and plug can be installed, or if the unit must be hard wired.
4. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near
the brewer, and its location and markings known to the operators.
5. The body of the brewer must be grounded to a suitable building
ground. A ground lug is provided in the brewer next to the power
terminal block. Use only 10 gauge copper wire for grounding.
6. Electrical connections must be secured in-place within the unit to
meet national and local standards.
7. Connect the incoming power wires to the terminal block in accordance with applicable codes.
CBS-2061e and CBS-2062e Single Phase
SINGLE PHASE
TERMINAL BLOCK
Safety notes.
Professional installation is required. This appliance is manufactured for commercial use only.
Operation requirements and maintenance for commercial cooking appliances differ from household appliances.
Operators must be trained for this equipment and must understand the use, maintenance and kitchen hazards.
Do not attempt to move the CBS-2061e or CBS-2062e once it is filled. Drain equipment before moving.
The CBS-2060e coffee brewers prepare up to three gallons of coffee or tea in a single batch using very hot water.
The factory set brew (default) time is 4.5 minutes with the brew basket locked for safety from start of brew.
The brew basket unlocks and may be serviced 8.5 minutes after starting the brew.
Never attempt to defeat or override the brew basket locking feature.
EXTRACTOR® coffee brewers include a hot water service tap for kitchen purposes.
The hot water service tap is operated by the electronic touchpad and may be completely disabled by entering
operator access programming. (see PROGAMMING - beginning page 9)
Keep these instructions for training and future reference
Electrical Configurations – US & Canada
GROUND LUG
L1
N
L2
120V
120V
N
GROUND
WIRE
208-240V
CBS-2061e and CBS-2062e Three Phase
3 PHASE
TERMINAL BLOCK
208-240V
208-240V
Incoming Power: Connect wires to L1, L2, L3, N, Grnd
Heater Wires:
Connect wires 1 & 2 to L1
Connect wires 3 & 4 to L2
Connect wires 5 & 6 to L3
6
Warning: To prevent
electrical shock, this
unit must be properly
grounded.
GROUND LUG
L1 L2 L3
N
208-240V
120V
GROUND
WIRE
N