  • Page 1 ECO Series Programming Guide (800) 338-2699 (847) 719-3000 techsupport@fetco.com www.fetco.com © 2008 Food Equipment Technologies Company Part # P105 September, 2008...
  • Page 2: Default Settings

    Default Settings CBS-2031ee CBS-2041ee Parameter Name CBS-2032ee CBS-2042ee Brew Volume 2.49 LTR 1.0 GAL Brew Time (Min:Sec) 4:00 4:00 Prewet Percent Prewet Delay (Min:Sec) 1:00 1:00 Drip Delay (Min:Sec) 1:00 1:30 Water Temp. 200 F 200 F ECO Mode Brew at Set Temperature Temperature Scale Water Volume Scale Liters...
  • Page 3: To Enter Programming Mode

    To Enter Programming Mode Turn the brewer off by pressing the power switch. Press and hold the power switch until the display reads P r G. The left side STOP button will illuminate. Quickly press the STOP button. The display will show the software version. Example: 0.0 03.L Press STOP to continue.
  • Page 4 Next, the first batch parameter is displayed – batch 1, brew volume Use the SCROLL UP and SCROLL DOWN buttons to adjust. Example: 1.1 1.00 Press the STOP button to go to the next parameter – brew time. Example: 1.2 4.00 Repeat the last step until all parameters are programmed for batch #1.
  • Page 5: Batch Parameters

    Batch Parameters (X = Batch Number) Parameter Name Range Comment Batch Enabled or On/Off Top batch on each side Disabled cannot be disabled. Brew Volume Liters: To switch between 0.94 – 4.72 gallons and liters, see # 59 in Advanced Gallons: Settings section.
  • Page 6: Temperature Settings

    Temperature Settings Parameter Name Range Comment Water Temp. Temperature inside tank. Will be 188°-206°F slightly lower at spray head. 87°-96°C To display in Celsius, see # 58 in Advanced Settings. ECO Mode OFF/ON ON= After 1 hour without brewing, the temperature setting will automatically be lowered by 30°F, and the display will read ECO.
  • Page 7 Enter Advanced 0 - 1 0 = Skip Advanced Settings & Settings & Diagnostics. Loop back to start of Diagnostics batch programming. 1 = Enter Advanced Settings & Diagnostics. Press STOP to continue. Important! To save changes, press and hold STOP until the display reads STO to exit programming mode and return to operating mode.
  • Page 8: Advanced Settings And Diagnostics

    Advanced Settings and Diagnostics Address Description Range Comment Water Level in Tank 0 - 1 Tests if tank is full. 0 = Tank is not full. 1 = Tank is full. Water Resistance 0 - 200 Displays the electrical resistance of the water in (KΩ) kilohms as measured between the water level...
  • Page 9 Water Level LO - HI LO – 0 to 50 KΩ Sensitivity HI – 50 to 130 KΩ If water resistance (address 51) is greater than 25 KΩ, set on HI to prevent unwanted filling of tank. Tank Temperature 180° - 206°F Displays current tank temperature.
  • Page 10 Temperature Scale F or C F = Displays temp in degrees Fahrenheit C = Displays temp in degrees Celsius Water Volume GAL or LTR GAL = Displays volume in Scale gallons LTR = Displays volume in liters Left Brew Valve Depends on Use this to compensate for Flow Rate...
  • Page 11 Keypad Test 0 - 1 Tests the function of control panel switches. Starting with the batch buttons, press each button. The display will show the name of the switch being pressed and the switch light will go out (there is no light for the power switch).
  • Page 12 Factory Use Only – Do not use. Important! To save changes, press and hold STOP until the display reads STO to exit programming mode and return to operating mode. FETCO®, EXTRACTOR® and DRIVEN TO PIONEER INNOVATION™ are trademarks or trade names of Food Equipment Technologies Company.

This manual is also suitable for:

Cbs-2031eeCbs-2032eeCbs-2041eeCbs-2042ee

Table of Contents