Basic Pager Display - Bosch CC880/LP880, SC8016 Operator's Manual

Table of Contents

Advertisement

CC880/LP880, SC8016 | Operators Guide | 27.0
Figure 8:

Basic Pager Display

Figure 8 shows the transmission came from the control panel with an ID number of 678 and that zone 2 is in
alarm. The figure also displays that zone 3 was manually isolated and the system armed.
Bosch Security Systems | 6/04 | 920036O.OG.162
1
1
2
678
01200000
Zone Normal - 0
Alarm - 1
Zone Bypassed - 2
Zone Trouble - 3
Disarmed - 8
Armed - 9
Normal - 0
Panic/Duress - 1
Fire Alarm - 2
Medical Alarm - 3
AC Normal - 0
AC Failure - 1
System Normal - 0
System Fault - 1
Basic Pager Reporting
2
3
4
5
6
7
8
9000
1 – Subscriber ID Number
2 – Zone Status
3 – System Status