Selector
No.
1
Not used.
ITU-T (CCITT) superfine
2
recommendation
3
|
Not used.
6
Max. document length
7
limitation
Stop/Exit key pressed during
8
reception
NOTE: Selector 7 is applicable to models equipped with ADF units.
Selector 2:
ITU-T (CCITT) superfine recommendation
If this selector is set to "1," the machine communicates in ITU-T (CCITT) recommended superfine
mode (15.4 lines/mm). If it is set to "0," it communicates in native superfine mode.
Selector 7:
Max. document length limitation
This selector is used to select the maximum length of a document to be sent.
Selector 8:
Stop key pressed during reception
If this selector is set to "1," pressing the Stop/Exit key can stop the current receiving operation.
The received data will be lost.
WSW16
(Function setting 1)
Function
App. 4-20
Setting and Specifications
0: OFF
0: 400 cm
0: Not functional
1: ON
1: 90 cm
1: Functional