Brother DCP7010 Service Manual page 272

Facsimile equipment
Hide thumbs Also See for DCP7010:
Table of Contents

Advertisement

WSW06
Selector
No.
1
Redial/Pause key setting and 2nd
|
dial tone detection
3
4
|
Detection of international tone
6
No. of 2nd dial tone detection
7
cycles
Allowable instantaneous interrupt
8
during reception of 2nd dial tone
NOTE: Selectors 4 through 8 are not applicable in those countries where no dial tone detection is
supported, e.g., U.S.A.
(Redial/Pause key setting and 2nd dial tone detection)
Function
App. 4-9
Setting and Specifications
No. 1 2 3
0 0 0 :
No pause
0 0 1 :
3.5 sec. WAIT
0 1 0 :
7 sec. WAIT
0 1 1 :
10.5 sec. WAIT
1 0 0 :
14 sec. WAIT
1 1 0 :
2nd dial tone detection
only in pulse dialing (DP)
system
1 0 1 :
2nd dial tone detection
1 1 1 :
both in DP and push-button
(PB) dialing system
No. 4 5 6
0 0 0 :
50 ms
0 0 1 :
210 ms
0 1 0 :
500 ms
0 1 1 :
800 ms
1 0 0 :
900 ms
1 0 1 :
1.5 sec.
1 1 0 :
2.0 sec.
1 1 1 :
2.5 sec.
0: 1 cycle
0: 30 ms
1: 2 cycles
1: 50 ms