M-8
Fixing unit failure
Possible cause
Step
Poor
1
thermistor
harness
contact
Blown thermal
2
fuse
Thermistor
3
assembling
failure
Halogen
4
heater lamp
failure
Heater harness
5
connection
failure
NOTE:
This problem will be cleared if leaving the printer power ON for ten minutes.
M-9
Main PCB failure
Possible cause
Step
Main PCB
1
Software bug
2
Check
Is the contact of connector
CN19 on the main PCB
good?
Remove the fixing unit and
measure the resistance
between the thermostat. Is
it open circuit?
Is the thermistor installed
properly?
Remove the fixing unit and
measure the resistance of
the halogen heater lamp. Is
it open circuit?
Is the heater harness
connector connected to the
low-voltage power supply
PCB and fixing unit
secure?
Check
Is it possible to print the
test page with the method?
Does this problem appear
when printing specific data
or printing under a specific
environment?
9 -2 4
Result
Remedy
No
Reconnect the connector.
Yes
Replace the fixing unit.
Yes
Replace the fixing unit.
No
Reinstall the thermistor
properly.
Yes
Replace the halogen heater
lamp.
No
Reconnect the connectors
securely.
Result
Remedy
No
Replace the main PCB.
Yes
Inform the Brother office of the
used specific data, printer
condition and system
environment.