8.7.7
Resetting the Escape Sequence
The SCM set escape command allows the user to change the escape
sequence. The default escape sequence is "<Esc><Esc>scm".
The new escape sequence can be any printable character string, not to exceed
six characters. Use the show status command to verify the new escape
sequence.
SCM_E0> set escape
Escape Sequence: foofoo
SCM_E0> show status
.
.
.
RMC Escape Sequence: foofoo
Using the System Control Manager
8-29
Need help?
Do you have a question about the AlphaServer GS80 and is the answer not in the manual?
Questions and answers