Error Messages - Sony SRR1000 Operation Manual

Memory storage unit
Hide thumbs Also See for SRR1000:
Table of Contents

Advertisement

Error Messages

When the unit ceases to operate correctly due to a
malfunction or internal system error, the alarm will sound
and an error message will appear on the display.
After an error message is displayed, eliminate the cause of
the error based on the error message and then turn the unit
back on. If the error message appears again when the unit
is turned on, contact your Sony representative.
1)
Code
Indication
14xx00
PS FAN1 TROUBLE, etc.
14xxpp
260100
POWER SUPPLY UNIT TROUBLE
2701ss
SLOT Mx EJECT ERROR
2801ss
SLOT Mx EXIST ERROR
2901ss
SLOT Mx EJECT MOTOR LOCK
960100
CALENDAR CLOCK ERROR
A2zz00
SYS1 FRAM CHECKSUM ERROR, etc.
A90100
SY-350 OVER CURRENT ERROR
B3xx00
SY CPLD2 INITIAL ERROR, etc.
B3xxpp
B4xx00
POWER SUPPLY TEMPERATURE HIGH, etc.
B4xxpp
B4xxss
B8zz00
SYS1-SYS2 NO COMMUNICATION ERROR,
etc.
B9zz00
CP-SYS1 NO COMMUNICATION ERROR, etc.
BAzz00
KY-CP NO COMMUNICATION ERROR, etc.
D1xxpp
PORT x ENC DMA1 ERROR, etc.
D2xxpp
PORT x DEC DMA1 ERROR, etc.
D3xxss
SLOT Mx AV WRITE ERROR1, etc.
D4xxss
SLOT Mx AV READ ERROR1, etc.
58
Troubleshooting
Meaning
A malfunction of cooling fan motor was detected. For
details, see the Maintenance Manual.
A power failure was detected.
Pressing the Eject button failed to eject an SRMemory card
from the indicated slot. When the slot indicator is off,
forcibly ejecting an SRMemory card will not damage
recorded data.
The SRMemory card in the indicated slot could not be
detected even though the Eject button had not been
pressed.
A malfunction of eject motor was detected at the indicated
slot. When the slot indicator is off, forcibly ejecting an
SRMemory card will not damage recorded data.
An internal calendar clock error was detected.
An error was detected in FRAM used by SYS1. For details,
see the Maintenance Manual.
An over current was detected in the DC-DC converter on
the SY-350 board. For details, see the Maintenance
Manual.
An error was detected at the device initialization stage. For
details, see the Maintenance Manual.
Temperature sensor has detected an error. For details, see
the Maintenance Manual.
SYS1 CPU has detected a communication error between
CPUs (SYS1, SYS2, CP). For details, see the Maintenance
Manual.
CP CPU has detected a communication error between
CPUs (SYS1, CP, KP). For details, see the Maintenance
Manual.
KY CPU has detected a communication error between
CPUs (CP, KY). For details, see the Maintenance Manual.
An error was detected during recording via the indicated
port. For details, see the Maintenance Manual.
An error was detected during playback via the indicated
port. For details, see the Maintenance Manual.
An error occurred while writing to the SRMemory card in
the indicated slot. For details, see the Maintenance Manual.
An error occurred while reading from the SRMemory card
in the indicated slot. For details, see the Maintenance
Manual.

Advertisement

Table of Contents
loading

Table of Contents