Tc Menu - Sony SRR1000 Operation Manual

Memory storage unit
Hide thumbs Also See for SRR1000:
Table of Contents

Advertisement

TC Menu

The TC menu allows you to set all of the items related to
time codes from a single menu.
Button
Indication
[F1]
TCG SRC
[F2]
REGENE
[F3]
RUN
[F4]
DF/NDF
[F5]
TM SEL
[F7]
TM RESET
[F8]
TM SET
[F9]
TM HOLD
[F10]
TCR SEL
ALT/[F3]
TC OUT
ALT/[F4]
TM DISP
44
Detailed Menu Description
Setting
Selects whether to synchronize the internal time code generator with the external
signal. (see page 27)
preset
ext-LTC
SDI-LTC
SDI-VITC
Selects the signal to regenerate when the time code generator is in regenerate
mode.
TC & UB: Regenerates both the time code signal and user bit signal.
TC: Regenerates only the time code signal.
UB: Regenerates only the user bit signal.
Selects the running mode of the time code generator.
Free: The time code advances when the power is on regardless of the unit's
operation mode.
Rec: The time code advances only during recording.
Selects the drop frame mode of the time code generator or timer counter.
DF: Drop frame mode
NDF: Non-drop frame mode
Notes
• This setting is only enabled when the frame frequency of the unit is 29.97 Hz or
59.94 Hz.
• This setting is only valid when [F1] (TCG SRC) is set to "preset."
Selects the time data to display on the display. To switch between VITC and LTC,
press the [F10] (TCR SEL) button. (see page 27)
TC
UB
TM1
TM2
Resets the time counter.
Inputs time data. (see page 27)
The time counter is temporarily stopped while the button is pressed.
Sets the value read by the time code reader.
LTC
VITC
Sets the time code that is output from the TIME CODE OUT connector during
recording when the internal time code generator is set to a mode for regenerating
the playback time code.
Through: Outputs the time code signal input from the TIME CODE IN connector as
is.
Regene: Regenerates the time code signal input from the TIME CODE IN
connector before outputting it.
Sets whether TM1 is in 12-hour display mode or 24-hour display mode.
Note
When ±12H is set, the tens digit of the hours value is dropped.
+–12H
24H
Target
In
In
In
I/O
I/O
I/O
I/O
Out
Out
In
I/O

Advertisement