Water Connection Requirements

Connections should be supplied by a hot and a cold
water line of at least the sizes shown in Table 8.
Installation of additional machines will require
proportionately larger water lines.
To connect water service to a machine with rubber
hoses, use the following procedure:
1. Before installing hoses, flush the water system
for at least 2 minutes.
2. Check filters in the machine's inlet hoses for
proper fit and cleanliness before connecting.
3. Hang hoses in a large loop; do not allow them to
kink.
If additional hose lengths are needed, use flexible
hoses with screen filters.
IMPORTANT: Hoses and other natural rubber
parts deteriorate after extended use. Hoses may
develop cracks, blisters or material wear from the
temperature and constant high pressure they are
subjected to.
All hoses should be checked on a monthly basis for
any visible signs of deterioration. Any hose showing
signs of deterioration listed above should be
replaced immediately. All hoses should be replaced
every five years.
Cabinet Hardmount
Water Supply Information
Water Inlet Connection Size,
in. (mm)
Number of water inlets
Recommended pressure,
psi (bar)
Inlet flow capacity,
gal-min/l-min (80 psi)
F232135R12
18-80
80
.75 (19)
.75 (19)
2
2
30 - 85
30 - 85
(2 - 5.7)
(2 - 5.7)
23 (87)
32 (121) 50 (189)
Table 7
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Number
of
Machines
1
2
3
4
1
2
3
4
1
2
3
4
Suitable air cushions should be installed in supply
lines to prevent "hammering." Refer to Figure 41.
125
1 (25.4)
1
2
30 - 85
(2 - 5.7)
1
2
To prevent personal injury, avoid contact
with inlet water temperatures higher than
125° Fahrenheit (51° Celsius) and hot
surfaces.
Water Supply Line Sizing
Supply Line Size
Main
.75 in. (19 mm)
1 in. (25 mm)
1.25 in. (32 mm)
1.5 in. (38 mm)
1 in. (25 mm)
1.5 in. (38 mm)
2 in. (50 mm)
2 in. (50 mm)
1.5 in. (38 mm)
2 in. (50 mm)
2 in. (50 mm)
2.5 in. (70 mm)
Table 8
Water Supply Faucets
Air Cushions (Risers)
Figure 41
WARNING
Installation
Hot/Cold
.75 in. (19 mm)
.75 in. (19 mm)
1 in. (25 mm)
1 in. (25 mm)
.75 in. (19 mm)
1 in. (25 mm)
1.25 in. (32 mm)
1.5 in. (38 mm)
1 in. (25 mm)
1.5 in. (38 mm)
2 in. (50 mm)
2 in. (50 mm)
2
CHM2232N
CHM2232N
W748