Installation

Elevated Base Frame Installation

Factory-built elevated steel base frames are designed
to meet the specifications of the 20-60 2 speed,
F-speed and A-control variable-speed model
washer-extractors only. Refer to Figure 31. The
spacing between two machines provided by an
elevated base is .38 inch (9.5 mm) in 20, 25, 30 and 60
pound models and .25 inch (6.3 mm) in 40 pound
models.
Figure 31
48
H035I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: For 80 and 125 pound models, a
bolt-locator fixture or rebar frame is available as
an option. This is designed to be embedded in
concrete. Refer to Figure 32.
IMPORTANT: Do not install any variable-speed
machine on an elevated base frame. * C60 (and
smaller capacity models), A-control variable-speed
machines can be installed on an elevated base
frame. Refer to Elevated Base Frame Installation
section.
1
2
3
4
1
Machine Base
2
Mounting Bolt Threads
3
Grouting
4
Bolt-Locator Fixture or Rebar Frame
Figure 32
Installing With Elevated Base Frame
1. Verify the floor meets the requirements given in
the Machine Foundation section.
NOTE: When using elevated base frames from
Alliance Laundry Systems, the elevated base
should be mounted with the part number sticker in
the up position.
2. Use the elevated base frame as a template by
positioning the frame in the desired location and
marking the pre-drilled mounting holes on the
floor.