Redundant Linking of Network Segments

The example of redundant linking of two network segments as shown here is pos-
sible only when linking between X414 because the standby function of the X414 is
required.
SCALANCE X414-3E
Figure 1-6
In this case, network segments are rings with a redundancy manager (RM). The
rings can also be interrupted at one point (linear topology).
For a redundant link as shown in the figure, two devices must be configured within
a network segment. This configuration is set in Web Based Management, Com-
mand Line Interface or using SNMP access. For more detailed information, refer to
the Configuration Manual SCALANCE X-400 Industrial Ethernet Switches.
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03
RM
S7-300
RM
Redundant linking of two subnets
Introduction to Industrial Ethernet Switches
SCALANCE X414-3E