Toshiba TOSVERT VF-MB1/S15 IPE002Z Function Manual page 49

For tosvert vf-mb1/s15
Hide thumbs Also See for TOSVERT VF-MB1/S15 IPE002Z:
Table of Contents

Advertisement

■Examples of Instance 100/150
① Stop
Instance
Output Instance 100
Input Instance 150
② Forward running 60Hz
Instance
Output Instance 100
Input Instance 150
③ Reverse running 60Hz
Instance
Output Instance 100
Input Instance 150
④ Preset speed 1 with forward running (sr1)
Instance
Output Instance 100
Input Instance 150
(sr1 is set 5Hz.)
⑤ Fault reset *
Instance
Output Instance 100
About the other command, refer to section 3.2.4.2.
* Fault reset works only 1 time when 0 -> 1.
Byte
15 14 13 12 11 10 9 8 7 6
1, 0
0
0
0
0
3, 2
-
-
-
-
1, 0
0
0
0
1
3, 2
0
0
0
0
Byte
15 14 13 12 11 10 9 8 7 6
1, 0
0
0
1
1
3, 2
0
0
0
1
1, 0
0
0
1
1
3, 2
0
0
0
1
Byte
15 14 13 12 11 10 9 8 7 6
1, 0
0
0
1
1
3, 2
0
0
0
1
1, 0
0
0
1
1
3, 2
0
0
0
1
Byte
15 14 13 12 11 10 9 8 7 6
1, 0
0
0
0
1
3, 2
-
-
-
-
1, 0
0
0
1
1
3, 2
0
0
0
0
Byte
15 14 13 12 11 10 9 8 7 6
1, 0
0
0
0
1
3, 2
-
-
-
-
5
0
0
0 0 0 0
0
-
-
-
-
-
-
-
0
0 0 0 0
0
1
0
0
0 0 0 0
0
5
0
0 0 0 0
0
1
0
1 1 0 1
1
1
0
0 0 0 0
0
1
0
1 1 0 1
1
1
5
0
1 0 0 0
0
1
0
1 1 0 1
1
1
0
1 0 0 0
0
1
0
1 1 0 1
1
1
5
0
0 0 0 0
0
1
-
-
-
-
-
-
-
0
0 0 0 0
0
1
0
0
0 1 1 1
1
5
0
0
0 0 0 0
0
-
-
-
-
-
-
-
- 48 -
E6581741
4
3
2
1
0
Hex.
0
0
0
0
0
0x0000
-
-
-
-
-
-
0
0
0
0
0
0x4800
0
0
0
0
0
0x0000
4
3
2
1
0
Hex.
0
0
0
0
0
0xC400
0
0
0
0
0x1770
1
0
0
0
0
0
0x6400
0
0
0
0
0x1770
1
4
3
2
1
0
Hex.
0
0
0
0
0
0xC600
0
0
0
0
0x1770
1
0
0
0
0
0
0x6600
0
0
0
0
0x1770
1
4
3
2
1
0
Hex.
0
0
0
0
0x8401
1
-
-
-
-
-
-
0
0
0
0
0
0x6400
0
0
0
0x01F4
1
1
4
3
2
1
0
Hex.
0
0
0
0
0
0x2000
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ethernet/ip modbus ipe002z

Table of Contents