3.2.4.7. fd01 (Inverter operating status 1)
bit
Function
0
Failure FL
1
Failure
2
Alarm
3
Under voltage (moff)
Motor selection (1 or 2)
4
(THR 2 selection)
5
PID control off
Acceleration/deceleratio
6
n pattern selection (1 or
2)
7
DC braking
8
Jog run
9
Forward / reverse run
10
Run/stop
11
Coast stop (ST = OFF)
12
Emergency stop
13
Standby ST=ON
14
Standby
15
(Reserved)
Note: Don't use the reserved bit for the judgment.
3.2.4.8. fd00 (Output frequency)
The current output frequency is read into 0.01Hz of units and by the hexadecimal number.
For example, when the output frequency is 80Hz, 0x1F40 (hexadecimal number) are read.
Since the minimum unit is 0.01%,
0x1F40 (Hex.) = 8000(Dec.) * 0.01 = 80 (Hz)
Also about the following parameters, these are the same as this.
- fd22 (Feedback value of PID)............................................... Unit: 0.01Hz
- fd16 (Estimated speed) ........................................................ Unit: 0.01Hz
- fd29 (Input power) ................................................................ Unit: 0.01kW
- fd30 (Output power) ............................................................. Unit: 0.01kW
0
Under in
No output
progress
Not tripped
Tripped
No alarm
Alarm issued
Normal
Under voltage
Motor 1 (THR1)
Motor 2 (THR2)
PID control
PID control
permitted
prohibits
Acceleration/dec
Acceleration/dec
eleration pattern
eleration pattern
1 (AD1)
2 (AD2)
Forced DC
OFF
braking
OFF
Jog run
Forward run
Reverse run
Stop
ST=ON
ST=OFF
No emergency
Emergency
stop status
stop status
Start-up process
Standby
Start-up process
Standby
Undefined
- 18 -
1
Trip status includes rtry and
the trip retention status are also
regarded as tripped statuses.
THR1: pt = setting value, vl,
vlv, vb, thr
THR2: pt = 0, f170, f171,
f172, f173
AD1: acc, dec
AD2: f500, f501
Run
Standby: Initialization
completed, not failure stop
status, not alarm stop status
(moff, ll forced stop),
ST=ON, and RUN=ON
Standby: Initialization completed,
not failure stop status and not
alarm stop status (moff, ll
forced stop)
E6581741
Note
-
-
-
-
-
-
-
-
-
-
-