Toshiba TOSVERT VF-MB1/S15 IPE002Z Function Manual page 10

For tosvert vf-mb1/s15
Hide thumbs Also See for TOSVERT VF-MB1/S15 IPE002Z:
Table of Contents

Advertisement

Communi
Title
cation No.
Protocol (*3)
c500
C500
Rate Setting (*3)
c501
C501
Actual Rate (L port)
c502
C502
Actual Rate (R port)
C503
c503
IP mode (*3)
C504
c504
C505-
c505-
IP address (*3)
C508
c508
C509-
c509-
Subnet Mask (*3)
c512
C512
C513-
c513-
IP Gate (*3)
c516
C516
C517-
c517-
MAC address (*5)
C522
c522
c523
C523
Time out
C524-
c524-
IP address actual
C527
c527
C528-
c528-
IP Mask actual
C531
c531
c532-
C532-
IP Gate actual
C535
c535
(*3): This parameter is effective by reset. Please reset (power supply reset or f899=1) after changing a set point.
(*5): .These values are displayed by decimal number format on panel of VFMB1/S15.
Function
This parameter is used to set the protocol of the option
card.
0: Modbus TCP (default)
1: EtherNet/IP
This field is used to set the transmission speed and the
transmission mode of the card.
0: Autodetect(default)
1: 10Mbps Full
2: 10Mbps Half
3: 100Mbps Full
4: 100Mbps Half
This field displays the baud rate and the transmission
mode currently used by the communication card.
(Display only)
0: unconnected
1: 10Mbps Full
2: 10Mbps Half
3: 100Mbps Full
4: 100Mbps Half
Use this parameter to select the IP address assignment
method.
0: Manual
1: BOOTP
2: DHCP
Refer to " 3.2.2 Assigning IP addresses" for the details.
The IP address of the option module.
These fields are effective settings at c504 = 0.
Refer to " 3.2.2 Assigning IP addresses" for the details.
The subnet mask of the option module.
These fields are effective settings at c504 = 0.
Refer to " 3.2.2 Assigning IP addresses" for the details.
The gateway IP address of the option module.
These fields are effective settings at c504 = 0.
Refer to " 3.2.2 Assigning IP addresses" for the details.
The MAC address of the option module.
[C517 - C518 - C519 - C520 - C521 - C522]
The waiting time from the occurrence of the
network error to detection can be adjusted.
* When you are using unconnected
communication of the EtherNet/IP protocol, time
out is not detected.
0.0: Disable
0.5 - 60 sec.
The current IP address of the option module.
Refer to " 3.2.2 Assigning IP addresses" for the details.
The subnet mask actual of the option module.
Refer to " 3.2.2 Assigning IP addresses" for the details.
The gateway IP address actual of the option module.
Refer to " 3.2.2 Assigning IP addresses" for the details.
- 9 -
E6581741
Description
Factory
setting
0
0
-
0
0.0.0.0
0.0.0.0
0.0.0.0
----
2
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ethernet/ip modbus ipe002z