Function description
Cylinder priority control
Make the following settings at the
solar control unit:
Main menu
■ "Solar"
■ "Setting values"
– "Priority Cyl1" etc.
Set a value.

Collector emergency stop

The solar thermal system enters stagna-
tion when temperature "Tcolemoff" is
reached. Heating of consumers is then
no longer possible.

Bypass

Bypass versions
■ With collector temperature and bypass
sensor
Implementation via relays R2, R6 or
R7 (subject to the selected system and
hydraulic type, see from page 94).
■ With solar cell
Requires no relay assignment.
■ With solar cell and collector tempera-
ture sensor
Implementation via relays R2, R6 or
R7 (subject to the selected system and
hydraulic type, see from page 94).
118
(cont.)
Make the following settings at the
solar control unit:
Main menu
■ "Solar"
■ "Setting values"
– "Tcolemoff"
Set a value.