Viessmann VITOSOLIC 200 Installation And Service Instructions Manual page 165

Electronic temperature differential control unit
Table of Contents

Advertisement

Overview of system parameters
Contractor:
■ SC offset
■ Temp.units
■ Sensor 1
■ Sensor 2
■ Sensor 3
■ Sensor 4
■ Sensor 5
■ Sensor 6
■ Sensor 7
■ Sensor 8
■ Sensor 9
■ Sensor 10
■ Sensor 11
■ Sensor 12
Outputs
■ Min speed 1
■ Min speed 2
■ Min speed 3
■ Min speed 4
■ Relay kick
■ Time
■ Control 1
■ Control 2
■ Control 3
■ Control 4
■ VBus
Description
Do not adjust
Temperature unit
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Sensor matching
Minimum speed of
the pump at R1
Minimum speed of
the pump at R2
Minimum speed of
the pump at R3
Minimum speed of
the pump at R4
The pumps are star-
ted at an adjustable
time for 10 s to pre-
vent them from seiz-
ing up
Time for relay kick
See the table on
page 69
See the table on
page 69
See the table on
page 69
See the table on
page 69
Activating the V BUS Yes
(cont.)
Deliv-
Setting
ered con-
range
dition
°C
°F
Celsius
Fahrenheit
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
−5 K to 5 K
0 K
30 %
30 to 100 %
30 %
30 to 100 %
30 %
30 to 100 %
30 %
30 to 100 %
No
ON/OFF
ON/OFF
ON/OFF
ON/OFF
Appendix
Set value
165

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitosolic 200 sd4

Table of Contents