Viessmann VITOSOLIC 200 Installation And Service Instructions Manual page 154

Electronic temperature differential control unit
Table of Contents

Advertisement

Appendix
Overview of system parameters
Setting values
Solar set-
Description
ting:
Tcolmax
Maximum collector
temperature
page 128)
Tcolemoff
Collector shutdown
temperature
page 118)
Note
This function is disa-
bled at setting 200
°C.
Options
Solar options:
System
Hyd. Type
Bypass
Ext. HE
Cooling fct.
Col.interv.
Col.cool.fct
Ret.cool.fct
Frost prot.
Target temp.
Par. Relay
SC bypass
Never set the maximum collector temperature higher than the collector shutdown
*7
temperature. Both values are mutually interlocked to a differential of at least 10 K.
154
*7
(see
*7
(see
Description
System settings (see page 94)
Selecting the hydraulic type (see
the corresponding system)
Bypass circuit with collector tem-
perature and bypass sensor (see
page 119)
Ext. heat exchanger connected
(see page 122)
Cooling function (see page 126) No
Interval function (see page 127)
Collector cooling function (see
page 128)
Reverse cooling function (see
page 129)
Frost protection (see page 129)
Target temperature (see
page 130)
Parallel relay (see page 130)
Bypass circuit with solar cell (see
page 120 and 121)
(cont.)
Delivered
Setting range
condition
110 °C
80 to 160 °C
130 °C
110 to 200 °C
Delivered
condition
1
(1 to 7)
1
(1 to 4)
No
No
No
No
No
No
No
No
No
Set value
Set value