Viessmann VITOSOLIC 200 Installation And Service Instructions Manual page 152

Electronic temperature differential control unit
Table of Contents

Advertisement

Appendix
Overview of system parameters
Setting values
Solar set-
Description
ting:
ΔTon
Start temperature dif-
ferential for solar cir-
cuit pump
ΔToff
Stop temperature dif-
ferential for the solar
circuit pump
ΔTset
Differential tempera-
ture for the start of
speed regulation (see
page 139)
ΔT2on
Start temperature dif-
ferential for con-
sumer 2
ΔT2off
Stop temperature dif-
ferential for con-
sumer 2
ΔT2set
Differential tempera-
ture for the start of
speed regulation (see
page 139)
ΔT3on
Start temperature dif-
ferential for con-
sumer 3
ΔT3off
Stop temperature dif-
ferential for con-
sumer 3
ΔT3set
Differential tempera-
ture for the start of
speed regulation (see
page 139)
ΔT4on
Start temperature dif-
ferential for con-
sumer 4
ΔT4off
Stop temperature dif-
ferential for consumer
4
*5
*4
"ΔTon" can be at least 0.5 K above "ΔToff".
"ΔToff" can be at least 0.5 K below "ΔTon".
*5
152
Delivered
condition
8 K
*4
4 K
*5
10 K
8 K
*4
4 K
*5
10 K
8 K
*4
4 K
*5
10 K
8 K
*4
4K
(cont.)
Setting range
1.5 to 20 K
1 to 19.5 K
2 to 30 K
1.5 to 20 K
1 to 19.5 K
2 to 30 K
1.5 to 20 K
1 to 19.5 K
2 to 30 K
1.5 to 20 K
1 to 19.5 K
Set value

Hide quick links: