Viessmann VITOSOLIC 200 Installation And Service Instructions Manual page 159

Electronic temperature differential control unit
Table of Contents

Advertisement

Overview of system parameters
Setting values
Sys. set-
Description
ting:
Time switch
1
t1–on
t1–off
Period function block 1
t2–on
t2–off
t3–on
t3–off
Th3on
Thermostat start tempera-
ture function block 2
Th3off
Thermostat stop tempera-
ture function block 2
Th4on
Thermostat start tempera-
ture function block 2
Th4off
Thermostat stop tempera-
ture function block 2
ΔT6on
Start temperature differen-
tial function block 2
ΔT6off
Stop temperature differen-
tial function block 2
Time switch
2
t1–on
t1–off
Period function block 2
t2–on
t2–off
t3–on
t3–off
Th5on
Thermostat start tempera-
ture function block 3
Th5off
Thermostat stop tempera-
ture function block 3
Th6on
Thermostat start tempera-
ture function block 3
Th6off
Thermostat stop tempera-
ture function block 3
(cont.)
Deliv-
Setting range
ered
condi-
tion
00:00
00:00 to 23:00
40 °C
45 °C
−40 to 250 °C
40 °C
45 °C
5 K
1.5 to 20 K
3 K
1 to 19.5 K
00:00
00:00 to 23:00
40 °C
45 °C
−40 to 250 °C
40 °C
45 °C
Appendix
Set
value
159

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitosolic 200 sd4