NEC Express5800/320Ma Technical Reference Manual page 34

Hide thumbs Also See for Express5800/320Ma:
Table of Contents

Advertisement

ftSMC Component Properties
Table 3-1. ftSMC System Inventory Component Properties (Continued)
Property
Limit of Event Log Entries
Line1
Line2
LinkDataRate
LinkProtocol
Long Idle Re-send Count
Long Idle Time Between
Re-sends
LowerThresholdCritical
LowerThresholdFatal
LowerThresholdNonCritical
LowResynchPriorityMbs
3-10
Express5800/320Ma: Technical Reference Guide
Description
The maximum number of event log entries to include in any
message. By default, if the specified interval has more than 256
entries in either the system or the application log, the last 256
entries are sent as part of the message.
Contains the text on the top line of the front panel LCD.
Contains the text on the bottom line of the front panel LCD.
The current signalling rate of the link.
The storage command protocol running on the link.
The number of re-send attempts, separated by
Between
Re-sends, that ftServer Manager will make before
dropping the current alarm message.
The long idle time, in seconds, between attempts to re-send an
alarm. After a number, defined by
Re-sends, of unsuccessful attempts to send an alarm message,
ftServer Manager waits this long before it attempts to re-send the
alarm. After a number of unsuccessful attempts, defined by
Idle Re-send
Count, ftServer Manager will quit attempting to send
the oldest alarm message and move to the next one in the alarm
queue.
Threshold values specify the ranges for determining whether the
monitored component is operating under normal, noncritical, critical,
or fatal conditions. Depending on the sensor, values are in degrees
o
Celsius (
C), millivolts (mV), revolutions per minute (rpm), or
milliamperes (mA).
Threshold values specify the ranges for determining whether the
monitored component is operating under normal, noncritical, critical,
or fatal conditions. Depending on the sensor, values are in degrees
o
Celsius (
C), millivolts (mV), revolutions per minute (rpm), or
milliamperes (mA). This property is not configurable and attempting
to change it will display the value of Not Set.
Threshold values specify the ranges for determining whether the
monitored component is operating under normal, noncritical, critical,
or fatal conditions. Depending on the sensor, values are in degrees
o
Celsius (
C), millivolts (mV), revolutions per minute (rpm), or
milliamperes (mA).
The low value for I/O bandwidth to disk, a portion of which will be
used for RDR disk resynchronization operation. The default value of
this property is 5Mbps.
Long Idle Time
Medium Idle Time Between
Long

Advertisement

Table of Contents
loading

Table of Contents