3Ware 720-0192-00 Manual page 99

Sas/sata raid controller
Table of Contents

Advertisement

Chapter 2. CLI Syntax Reference
91
Table 9: Supported RAID (Logical Unit) Types for Verification
Model
R0
R1
a
Yes
Yes
9000
9650SE
Yes
Yes
and
9690SA
a. Models 9500S, 9550SX, and 9590SE
For 9550SX and earlier controllers and for 9650SE and 9690SA running
pre-9.5.1, when you issue this command the specified verify will begin if the
verify schedule is disabled; otherwise it will pause until the next scheduled
verify. If after starting a verify, you enable the Verify Task Schedule, this on-
demand task will be paused until the next scheduled timeslot.
For 9650SE and 9690SA controllers running firmware 9.5.1 or later, if
verify=basic, the verify will begin immediately. If verify=advanced, the verify
will pause until the next scheduled verify. For more information, see "/cx set
verify=advanced|basic|1..5" on page 73.
Table 10: Manual Verify Behavior (/cx/ux start verify)
Basic Verify Schedule
(verify=basic)
Advanced Verify
Schedule
(verify=advanced)
Verify Schedule is
Disabled
(verify=disable)
Verify Schedule is
Enabled
(verify=enable)
Verify will pause if a rebuild, migration, or initialization is currently in
progress.
3ware SAS/SATA RAID Controller CLI Guide, Version 9.5.2
R5
R6
R10
R50
Yes
N/A
Yes
Yes
Yes
Yes
Yes
Yes
9650SE and
9650SE and
9690SA with
9690SA with
9.5.1 or later
firmware 9.5 or
9.5.0.1
Runs
N/A
immediately
Follows
Advanced Verify
N/A
Schedule
Runs
Runs
immediately
immediately
(Same as Basic)
Follows
Follows Verify
Advanced Verify
Schedule
Schedule
Single
Spare
JBOD
Yes
Yes
Yes
Yes
Yes
Yes
9550SX and
earlier
N/A
N/A
Runs
immediately
Follows Verify
Schedule

Advertisement