3Ware 720-0192-00 Manual page 91

Sas/sata raid controller
Table of Contents

Advertisement

Chapter 2. CLI Syntax Reference
83
u1-2
DISK
OK
u1-3
DISK
OK
u1-4
DISK
OK
u1-5
DISK
OK
u1-6
DISK
OK
u1-7
DISK
OK
u1-8
DISK
OK
u1-9
DISK
OK
u1-10
DISK
OK
u1-11
DISK
OK
u1/v0
Volume
-
u1/v1
Volume
-
One application of the /cx/ux show command is to see which sub-unit of a
degraded unit has caused the unit to degrade and which disk within that sub-
unit is the source of degradation. Another application is to see the source and
destination units during a migration.
The unit information shows the percentage completion of the processes
associated with the unit with %RCompl (percent Rebuild completion) and
%V/I/M (percent Verifying, Initializing, or Migrating).
Unlike other unit types, RAID-6 may potentially have 2 or more parity drives
and can tolerate two or more failures within a unit. As a result, an added
notation is used to describe %RCompl and %V/I/M, and these are (A) and
(P). (A) denotes that the percentage completion of the process is for the
current active process, and (P) denotes that the percentage completion of the
process is for the current paused process.
Example:
/localhost> /c0 show unitstatus
Unit
UnitType
Status
---------------------------------------------------------------------------
u0
RAID-6
REBUILD-VERIFY 50%(A)
Here, the RAID-6 unit u0 is in the Rebuild-Verify state, with percentage
Rebuild completion of 50% and is the current active process. The process of
either Verifying, Initializing, or Migrating is at 70% and it is a paused process.
For the unit display:
//localhost> /c0/u0 show
Unit
UnitType
Status
------------------------------------------------------------------------
u0
RAID-6
REBUILD-VERIFY 50%(A)
u0-0
DISK
OK
u0-1
DISK
OK
u0-2
DISK
OK
u0-3
DISK
REBUILDING
u0-4
DISK
OK
u0-5
DISK
OK
u0-6
DISK
OK
u0-7
DISK
OK
u0-8
DISK
REBUILD-PAUSE
u0-9
DISK
OK
u0-10
DISK
OK
u0-11
DISK
OK
3ware SAS/SATA RAID Controller CLI Guide, Version 9.5.2
-
-
p2
-
-
p3
-
-
p4
-
-
p5
-
-
p6
-
-
p7
-
-
p8
-
-
p9
-
-
p10
-
-
p11
-
-
-
-
-
-
%RCmpl
%V/I/M
Stripe
70%(P)
256k
%RCmpl
%V/I/M
Port
70%(P)
-
-
-
p0
-
-
p1
-
-
p2
80%
-
p3
-
-
p4
-
-
p5
-
-
p6
-
-
p7
20%
-
p8
-
-
p9
-
-
p10
-
-
p11
-
298.01
-
298.01
-
298.01
-
298.01
-
298.01
-
298.01
-
298.01
-
298.01
-
298.01
-
298.01
-
2047.00
-
1529.06
Size(GB) Cache
AVrfy
298.22
RiW
OFF
Stripe
Size(GB)
64K
2683.80
-
298.20
-
298.20
-
298.20
-
298.20
-
298.20
-
298.20
-
298.20
-
298.20
-
298.20
-
298.20
-
298.20
-
298.20

Advertisement

Table of Contents
loading

This manual is also suitable for:

9690sa9590se9550sx9550sxu9500s3ware 9650se

Table of Contents